A Case from Battery Replacement to Epıcardıal Pacemaker Implantatıon
Esra Polat 1 * ,
Sedat Sakallı 1,
Engin Dondurmacı 1,
Murat Abdulhamit Ercisli 2 More Detail
1 Department of Cardiology, Gaziantep City Hospital, Gaziantep, Turkey
2 Department of Cardiovascular Surgery, Gaziantep City Hospital, Gaziantep, Turkey
* Corresponding Author
OPEN ACCESS
55 Views
0 Downloads
Author Contributions: Conceptualization, E. P., S. S.; methodology, E. P., S. S.; validation, not applicable; formal analysis, not applicable; investigation, E. P., S. S.; resources, not applicable; data curation, E. P., S. S.; writing – original draft preparation, E. P., E. D.; writing – review and editing, E. P., M. A. E.; visualization, E. P., S. S.; supervision, not applicable; project administration, not applicable; funding acquisition, not applicable. All authors have read and agreed to the published version of the manuscript.
Ethical clearance: Informed consent was obtained.
ABSTRACT
Cardiac implantable electronic device (CIED) infections can present with a large spectrum ranging from erythema due to skin site inflammation to infective endocarditis, which can be fatal. Whether the pocket infection is complicated or not and whether there are signs of systemic infection are important in the prognosis and treatment of patients. In this case report, we present a patient with high comorbidity who underwent pacemaker battery replacement and developed complicated pocket infection and the difficulties in management.
REFERENCES
- Olsen T, Jørgensen OD, Nielsen JC, Thøgersen AM, Philbert BT, Frausing MHJP, Sandgaard NCF, Johansen JB. Risk factors for cardiac implantable electronic device infections: a nationwide Danish study. European Heart Journal. 2022; 43(47): 4946–4956. https://doi.org/10.1093/eurheartj/ehac576
- Joy PS, Kumar G, Poole JE, London B, Olshansky B. Cardiac implantable electronic device infections: who is at greatest risk? Heart Rhythm. 2017; 14(6): 839–845. https://doi.org/10.1016/j.hrthm.2017.03.019
- Deniz A, Karaaslan MB. The infections of cardiac implantable electronic devices: Four year experience of a single center. Journal of Clinical and Experimental Investigations. 2017; 9(2), 67–70. https://dergipark.org.tr/en/pub/jcei/issue/37561/433805
- Toriello F, Saviano M, Faggiano A, Gentile D, Provenzale G, Pollina AV, Gherbesi E, Barbieri L, Carugo S. Cardiac implantable electronic devices infection assessment, diagnosis and management: a review of the literature. Journal of clinical medicine. 2022; 11(19): 5898. https://www.mdpi.com/2077-0383/11/19/5898
- Chauhan A, Grace, AA, Newell SA, Stone DL, Shapıro LM, Schofıeld PM, Petch MC. Early Complications After Dual Chamber Versus Single Chamber Pacemaker Implantation. Pacing Clin. Electrophysiol. 1994; 17: 2012–2015. https://doi.org/10.1111/j.1540-8159.1994.tb03791.x
- Sandoe JAT, Barlow G, Chambers JB, Gammage M, Guleri A, Howard P, Olson E, Perry JD, Prendergast BD, Spry MJ, Steeds RP, Tayebjee MH, Watkin R. Guidelines for the Diagnosis, Prevention and Management of Implantable Cardiac Electronic Device Infection. Report of a Joint Working Party Project on Behalf of the British Society for Antimicrobial Chemotherapy (BSAC, Host Organization). British Heart Rh. J. Antimicrob. Chemother. 2015; 70: 325–359. https://doi.org/10.1093/jac/dku383
- Essebag V, Verma A, Healey JS Krahn AD, Kalfon E, Coutu B, Ayala-Paredes F, Tang AS, Sapp J, Sturmer M, Keren A, Wells GA, Birnie DH. Clinically significant pocket hematoma increases long-term risk of device infection: Bruise Control Infection Study. Journal of the American College of Cardiology. 2016; 67(11): 1300–1308. https://doi.org/10.1016/j.jacc.2016.01.009
- Kewcharoen J, Kanitsoraphan C, Thangjui S, et al. Postimplantation pocket hematoma increases risk of cardiac implantable electronic device infection: A meta-analysis. J Arrhythm. 2021; 37(3): 635–644. https://doi.org/10.1002/joa3.12516
- Blomström-Lundqvist C, Trayko, V, Erba PA, Burri H, Nielsen JC, Bongiorni MG, Poole J, Boriani G, Costa R, Deharo J, Epstein LM, Saghy L, Snygg-Martin U, Starck C, Tascini C, Strathmore N, ESC Scientific Document Group .European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS). EP Europace, 2020; 22(4): 515–549. https://doi.org/10.1093/europace/euz246
- Kutinsky IB, Jarandilla R, Jewett M, Haines DE. Risk of hematoma complications after device implant in the clopidogrel era. Circ Arrhythm Electrophysiol. 2010; 3: 312–18. https://doi.org/10.1161/CIRCEP.109.917625
- Birnie DH, Healey JS, Wells GA, Verma A, Tang AS, Krahn AD, Simpson CS, Ayala-Paredes F, Coutu B, Leiria TLL, Essebag V.. Pacemaker or defibrillator surgery without interruption of anticoagulation. N Engl J Med. 2013; 368: 2084–2093. https://doi.org/10.1056/NEJMoa1302946
- Wei Y, Cai L, Wu X, Zhou G, Lu X, Peng S, Ding Y, Xu J, Chen S, Ouyang P, Liu S. Sub-pocket small-hole drainage for pocket hematoma after cardiac device implantation. Herz. 2022; 47(1): 63–66. https://doi.org/10.1007/s00059-021-05037-y
- Prasertwitayakij N, Yanyongmathe J, Pongbangli N, Nantsupawat T, Gunaparn S, Pisespongsa C, Tawaditap C, Phrommintikul A, Wongcharoen W. Effect of pocket compression device on pocket hematoma after cardiac implantable electronic device implantation. Scientific Reports. 2025; 15(1): 3214. https://doi.org/10.1038/s41598-025-87735-9
- Zheng S, Huang X, Lin Y, Chen X, Lin G, Zhuang J. Negative-pressure wound therapy (NPWT) for the treatment of pacemaker pocket infection in patients unable or unwilling to undergo CIED extraction. Journal of Interventional Cardiac Electrophysiology. 2021; 61: 245–251. https://link.springer.com/article/10.1007/s10840-020-00805-y
- Kusumoto FM, Schoenfeld MH, Wilkoff BL, Berul CI, Birgersdotter-Green UM, Carrillo R, Cha YM, Clancy J, Deharo JC, Ellenbogen KA, Exner D, Hussein AA, Kennergren C, Krahn A, Lee R, Love CJ, Madden RA, Mazzetti HA, Moore JC, Parsonnet J, Patton KK, Rozner MA, Selzman KA, Shoda M, Srivathsan K, Strathmore NF, Swerdlow CD, Tompkins C, Wazni O. 2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction. Heart rhythm. 2017; 14(12): e503–e551. https://doi.org/10.1016/j.hrthm.2017.09.001
- Özcan KS., Osmonov D, Altay S, Yıldırım E, Türkkan C, Erdinler İ, Tatlısu A, Çanga Y, Çakmak N, Alper At, Gürkan K. Erişkinlerde Epikardiyal Kalp Pili Takilmasi: Sikliği Endikasyonlari ve Güvenirliği. Medical Network Kardiyoloji. 2013; 20(2): 76–80. https://www.medicalnetwork.com.tr/2013/konu.asp?goster=1&Metin=195