Ultrasonographic measurement of optic nerve sheath diameter as a bedside tool in critical care unit to identify raised intra cranial pressures
More Detail
1 Department of Anaesthesia and Critical Care, Government Medical College, Srinagar, J&K, India
* Corresponding Author
J CLIN MED KAZ, Volume 19, Issue 2, pp. 21-24.
https://doi.org/10.23950/jcmk/11900
OPEN ACCESS
939 Views
1023 Downloads
ABSTRACT
Aim: Raised intracranial pressure is a common problem in critical care unit and is associated with worse outcome. Several methods have been used to investigate for elevated intracranial pressure (ICP). Here usefulness of optic ultrasound as a bedside tool for assessment of raised ICP in critical care setting was studied.
Material and methods: A prospective study was carried out in Intensive Care Unit (ICU) of tertiary care hospital for a period of 12 months. Patients admitted in ICU during the period of study and who were at the risk of development of raised ICP and needed CT scan for diagnosis were part of the study. 115 patients were included. The optic nerve sheath was identified on ultrasound, and optic nerve sheath diameter (ONSD) was measured 3 mm posterior to the retina. A mean ONSD value of >0.5 cm was taken as positive. CT scan was done immediately afterwards to find any signs of raised ICP.
Results: The mean age of participants was 42.3±10 years with majority of them male (61.7%). The number of cases diagnosed as raised ICP with optic ultrasound was 36 (31.3%) and with CT scan 33 (28.7%) cases. The calculated sensitivity and specificity of optic ultrasound in detection of raised ICP is 100.0% (95% CI: 89.4-100.0) and 96.5% (95% CI: 90.0-99.3) respectively with accuracy of 97.5%.
Conclusion: The present study revealed that ultrasonographic measurement of ONSD as a bedside tool is accurate for screening of patients with probable elevation of ICP. It has advantage of being quick, is without any complication, and patient is not exposed to radiation, besides it does not expose patient to risk of transit during transport to imaging unit as in case of CT scan.
CITATION
Wani NJ. Ultrasonographic measurement of optic nerve sheath diameter as a bedside tool in critical care unit to identify raised intra cranial pressures. J CLIN MED KAZ. 2022;19(2):21-4.
https://doi.org/10.23950/jcmk/11900
REFERENCES
- Brain Trauma Foundation TBI Guidelines, 2016. Guidelines for the management of severe traumatic brain injury, fourth edition.
- Rangel-Castilla L, Gopinath S, Robertson CS. Management of intracranial hypertension. Neurol Clin. 2008;26:521–41. https://doi.org/10.1016/j.ncl.2008.02.003
- Bernuau J, Durand F. Intracranial pressure monitoring in patients with acute liver failure: a questionable invasive surveillance. Hepatology. 2006;44:502. https://doi.org/10.1002/hep.21243
- Holloway KL, Barnes T, Choi S, Bullock R, Marshall LF, Eisenberg HM, Jane JA, Ward JD, Young HF, Marmarou A. Ventriculostomy infections: the effect of monitoring duration and catheter exchange in 584 patients. J Neurosurg. 1996;85:419–24. https://doi.org/10.3171/jns.1996.85.3.0419
- Cartwright C, Igbaseimokumo U. Lumbar Puncture Opening Pressure Is Not a Reliable Measure of Intracranial Pressure in Children. J Child Neurol. 2015; 30:170–173. https://doi.org/10.1177/0883073814533006
- Raboel PH, Bartek J Jr, Andresen M, Bellander BM, Romner B. Intracranial pressure monitoring: invasive versus non-invasive methods-a review. Crit Care Res Pract. 2012. https://doi.org/10.1155/2012/950393
- Zhang X, Medow JE, Iskandar BJ, Wang F, Shokoueinejad M, Koueik J, Webster JG. Invasive and noninvasive means of measuring intracranial pressure: a review. Physiol Meas. 2017;38:143–82. https://doi.org/10.1088/1361-6579/aa7256
- Geeraerts T, Merceron S, Benhamou D, Vigué B, Duranteau J. Non-invasive assessment of intracranial pressure using ocular sonography in neurocritical care patients. Intensive Care Med. 2008;34:2062–7. https://doi.org/10.1007/s00134-008-1149-x
- Hayreh SS. Pathogenesis of oedema of the optic disk (papilloedema), a preliminary report. Br J Ophthal. 1964;48:522–43. https://doi.org/10.1136/bjo.48.10.522
- Hansen HC, Helmke K. Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. J Neurosurg. 1997;87:34–40. https://doi.org/10.3171/jns.1997.87.1.0034
- Helmke K, Hansen HC. Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension. I. Experimental study. Pediatr Radiol. 1996;26(10):701–5. https://doi.org/10.1007/BF01383383
- Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med. 2008;15(2):201–4. https://doi.org/10.1111/j.1553-2712.2007.00031.x
- Dubourg J, Javouhey E, Geeraerts T, Messerer M, Kassai B. Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: a systematic review and meta-analysis. Intensive Care Med. 2011; 37:1059–68. https://doi.org/10.1007/s00134-011-2224-2
- Banerjee A, Bala R, Saini S. Ultrasonographic measurement of optic nerve sheath diameter: a point of care test helps in prognostication of Intensive Care Unit patients. Indian J Anaesth. 2017;6:262–5.
- Ueda T, Ishida E, Kojima Y, Yoshikawa S, Yonemoto H. Sonographic optic nerve sheath diameter: a simple and rapid tool to assess the neurologic prognosis after cardiac arrest. J Neuroimaging. 2015;25:927–30. https://doi.org/10.1111/jon.12246
- Corradi F, Robba C, Tavazzi G, Via G. Combined lung and brain ultrasonography for an individualized “brain-protective ventilation strategy” in neurocritical care patients with challenging ventilation needs. Crit Ultrasound J. 2018;10:24. https://doi.org/10.1186/s13089-018-0105-4